Valves, Pumps & Actuation

The Actuation Layer defines all AOFS-compliant devices that perform actions on the farm. This includes irrigation pumps, valves, gates, and optionally generator start/stop controls. All actuators must comply with AOFS safety, logging, and operational rules, even if the system operates offline.

1. Core Actuators

  • Pumps
    • Controls water delivery from sources to storage tanks or irrigation manifolds.
    • Must support:
      • Start/stop commands from Field Controller.
      • Safety interlocks (tank FULL/LOW, low voltage, pressure limits).
      • Optional energy-aware operation: integrate with Power & Energy Sensors to adjust schedule or warn operators.
  • Valves
  • Operate irrigation zones, distribution manifolds, or auxiliary water lines.
  • Must support:
    • Open/close commands from Field Controller.
    • Flow or pressure monitoring feedback from Water Monitoring Sensors.
    • Fail-safe closure in case of errors, power loss, or critical alarms.
  • Optional Generator Start / Stop
  • Can be automatic (remote start) or manual (operator alert).
  • Must respect safety interlocks and event prioritization.

2. Actuation Control Principles

  • Local Authority:
    • All critical actuation commands are decided by the Field Controller.
    • No remote system may bypass fail-safes or directly actuate pumps/valves.
  • Fail-Safe Operation:
    • Hardware and software protections prevent flooding, over-irrigation, pump damage, or valve misoperation.
    • Actuators must respond to LOW/FULL tank switches, flow/pressure limits, and emergency stop signals.
  • Energy-Aware Operation (Optional):
    • Actuators may integrate with Energy-Aware Operation Module.
    • Event execution can be:
      • Delayed or skipped if insufficient energy is available.
      • Prioritized based on urgency or operator-defined importance.
    • System may alert operators if an actuator is consuming more power than expected, indicating possible maintenance needs (e.g., clogged pipe).

3. Scheduling & Automation

  • Event-Based Operation:
    • Pumps and valves operate according to scheduled irrigation events defined in the Field Controller.
    • Can be triggered manually by operators or via automation rules.
  • Integration with Sensors:
    • Actuators rely on Sensors & Environmental Monitoring for safe and efficient operation:
      • Soil moisture thresholds
      • Tank levels
      • Pressure and flow rates
      • Optional power measurements
  • Manual Override:
    • Operators can manually actuate pumps or valves, respecting hardware safety interlocks.
    • Manual events are logged and visible to Farm/HQ controllers.

4. Logging & Documentation

  • All actuator events must be logged locally on the Field Controller:
    • Event type (pump start/stop, valve open/close, generator start/stop)
    • Timestamp
    • Operator ID (if manual)
    • Sensor readings at the time of actuation (flow, pressure, battery, energy)
  • Logs are synchronized with Farm and HQ Controllers when connectivity is available.
  • Supports analytics, energy assessment, and audit for compliance purposes.

5. Optional Modules & Extensions

  • AOFS modules may define additional actuator types:
    • Greenhouse vents, fans, heaters, nutrient dosing pumps
    • Livestock feeders, water dispensers
    • Poultry egg collection or environmental actuators
  • Any custom actuator must:
    • Integrate with Field Controller fail-safes.
    • Support logging and optional energy-aware prioritization.
    • Follow AOFS modular interface rules.