| Line 6: | Line 6: | ||
| This blueprint is **non-normative** and intended as a **practical, | This blueprint is **non-normative** and intended as a **practical, | ||
| - | {{ : | ||
| - | {{ : | + | {{gallery>: |
| ===== Functional Purpose ===== | ===== Functional Purpose ===== | ||
| Line 26: | Line 25: | ||
| ===== Hydraulic Layout ===== | ===== Hydraulic Layout ===== | ||
| - | * Tank outlet feeds irrigation zones by gravity | + | * Tank outlet feeds irrigation zones by gravity |
| + | * **Minimum outlet height prevents complete emptying** to maintain tank stability | ||
| * Isolation valve allows manual control | * Isolation valve allows manual control | ||
| * Overflow routed to simple drainage or secondary container | * Overflow routed to simple drainage or secondary container | ||
| Line 50: | Line 50: | ||
| * AOFS control can read tank level for irrigation scheduling | * AOFS control can read tank level for irrigation scheduling | ||
| * Controller can enforce a minimum water level to ensure the tank remains gravity-stable against wind forces | * Controller can enforce a minimum water level to ensure the tank remains gravity-stable against wind forces | ||
| + | * Controller may connect to global weather forecasts when internet is available | ||
| + | * High wind or storm warnings trigger alerts to the operator | ||
| + | * Controller can temporarily fill or maintain tank level to prevent tipping during forecasted high winds | ||
| + | * Irrigation may be suspended or modified to reduce risk to infrastructure | ||
| * Manual bypass always available — irrigation continues even if electronics are offline | * Manual bypass always available — irrigation continues even if electronics are offline | ||